Skip to content
Scitek-WD-E60-1-1.jpg
Models

WD-E50 Endoscope Washer-Disinfector

The Scitek WD-E50 washes, disinfects and dries up to two flexible digestive endoscopes per cycle in a single 25 litre island-style tank. Its 7-inch full-view HD touch panel drives automatic cycles, records every run and prints or exports the documentation your infection-control file needs.
Endoscope reprocessing. Supplied, installed and serviced nationwide by Rob Dyer Surgical, with operator training, commissioning and standby support from our own technicians.
Key features

One 25 L island-style liquid-saving tank processes up to two digestive endoscopes per cycle.
7-inch full-view HD touch panel with automatic cycle selection and guided manual override.
Dual-stage spiral spray arms and two stainless infusion ports drive disinfectant through the working channels.
Integrated lumen drying with gas filtration to 0.1 µm at 99.99%, so channels finish dry and ready for storage.
Traceability built in — 3000 stored records, exportable and printable, with a traceability interface to your records system.
Reusable peracetic acid disinfection consuming up to 10 L per cycle; enzyme and alcohol reservoirs of 5 L each plus an 18 L disinfectant box are integrated.
Foot-operated door and 304 stainless shell with tempered glass, ABS and PMMA tanks.

Technical specifications

Tank configuration
1 × 25 L

Capacity
Up to 2 digestive endoscopes per cycle

Water supply pressure
0.2–0.5 MPa (purified water recommended)

Control panel
7-inch IPS full-view HD touch screen

Disinfectant box
≥ 18 L

Enzyme reservoir
≥ 5 L

Alcohol reservoir
≥ 5 L

Drying gas filtration
≤ 0.1 µm at 99.99%

Records
3000 cycles, exportable and printable, traceability interface

Construction
304 stainless steel shell, tempered glass door, ABS + PMMA tanks

Operating environment
5–40 °C, ≤ 80% RH

Power supply
AC 220 ± 22 V

Power consumption
3500 W

Validation and installation
Commissioning includes water quality checks, connection to your purified supply, disinfectant dosing setup and a documented qualification run with your own endoscope set before hand-over.
Request pricing and lead times — send a quote request and our consultant for your region replies within one business day.
The Scitek range is designed and manufactured by Scitek Global for healthcare and laboratory instrument reprocessing. Rob Dyer Surgical supplies and services the Scitek range across South Africa, with offices in Cape Town and Kyalami, Midrand.

WD-E60 Twin-Tank Endoscope Washer-Disinfector

The Scitek WD-E60 runs two 25 litre island-style tanks — A and B — that can work independently or at the same time, taking up to four flexible digestive endoscopes per cycle. It is built for high-volume endoscopy units that need throughput without losing the traceability and drying performance of a single-tank machine.
Endoscope reprocessing. Supplied, installed and serviced nationwide by Rob Dyer Surgical, with operator training, commissioning and standby support from our own technicians.
Key features

Dual 25 L island-style tanks that run independently or simultaneously, handling up to four endoscopes per cycle.
7-inch full-view HD touch panel with automatic cycle selection and traceability interface.
Dual-stage spiral spray arms and stainless infusion ports flush disinfectant through every working channel.
Integrated lumen drying with gas filtration to 0.1 µm at 99.99%.
Traceability built in — 3000 stored records, exportable and printable.
Reusable peracetic acid disinfection at up to 10 L per cycle, with integrated enzyme (5 L), alcohol (5 L) and 18 L disinfectant boxes.
Foot-operated door, 304 stainless shell, tempered glass, ABS and PMMA tanks.

Technical specifications

Tank configuration
2 × 25 L (A + B, independent or simultaneous)

Capacity
Up to 4 endoscopes per cycle

Water supply pressure
0.2–0.5 MPa (purified water recommended)

Control panel
7-inch IPS full-view HD touch screen

Disinfectant box
≥ 18 L

Enzyme reservoir
≥ 5 L

Alcohol reservoir
≥ 5 L

Drying gas filtration
≤ 0.1 µm at 99.99%

Records
3000 cycles, exportable and printable, traceability interface

Construction
304 stainless steel shell, tempered glass door, ABS + PMMA tanks

Operating environment
5–40 °C, ≤ 80% RH

Power supply
AC 220 ± 22 V

Validation and installation
Commissioning includes water quality checks, connection to your purified supply, disinfectant dosing setup and a documented qualification run with your own endoscope set before hand-over.
Request pricing and lead times — send a quote request and our consultant for your region replies within one business day.
The Scitek range is designed and manufactured by Scitek Global for healthcare and laboratory instrument reprocessing. Rob Dyer Surgical supplies and services the Scitek range across South Africa, with offices in Cape Town and Kyalami, Midrand.

Scitek Endoscope Washer-Disinfectors

In stock
Scitek Global logo Scitek Global

The Scitek endoscope washer-disinfector range automates high-level disinfection of endoscopes between cases: controlled washing, enzymatic pre-cleaning and thermal disinfection with cycle records, in a compact footprint for endoscopy units.

Both models are shown below — pick one for its full specification.

Specifications
Model
WD-E50 Endoscope Washer-Disinfector, WD-E60 Twin-Tank Endoscope Washer-Disinfector
Common questions

Questions about Scitek Endoscope Washer-Disinfectors

The three questions this unit raises most often. The full FAQ covers ordering, lead times, installation, validation, servicing, spares and guarantees.

Request a Quote
Do you supply endoscope reprocessing equipment?

The range includes endoscope washers and endoscope storage cabinets, which sit alongside the instrument washers and drying cabinets on the decontamination and storage side of a department.

Do you perform validation?

We perform calibration and statutory performance validation on sterilizers and washer-disinfectors. The records are prepared so they hold up to SANS and Department of Health scrutiny. Our article on IQ, OQ and PQ explains what each stage proves.

Does a repair mean the machine has to be revalidated?

Where a repair touches a critical component, requalification closes the job out. Annual performance requalification is normally folded into the same service agreement.