<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>sterilization Archives | Rob Dyer Surgical</title>
	<atom:link href="https://robdyersurgical.co.za/tag/sterilization/feed/" rel="self" type="application/rss+xml" />
	<link>https://robdyersurgical.co.za/tag/sterilization/</link>
	<description>Autoclave Manufacturer &#38; Medical Equipment Experts</description>
	<lastBuildDate>Fri, 16 Oct 2026 09:54:09 +0000</lastBuildDate>
	<language>en-ZA</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://robdyersurgical.co.za/wp-content/uploads/2023/01/cropped-icon-32x32.jpg</url>
	<title>sterilization Archives | Rob Dyer Surgical</title>
	<link>https://robdyersurgical.co.za/tag/sterilization/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Instrument Reprocessing from Start to Finish</title>
		<link>https://robdyersurgical.co.za/instrument-reprocessing-step-by-step/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 30 Oct 2026 06:00:00 +0000</pubDate>
				<category><![CDATA[CSSD & Sterile Services]]></category>
		<category><![CDATA[CSSD]]></category>
		<category><![CDATA[Infection Control]]></category>
		<category><![CDATA[Instrument Reprocessing]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">https://robdyersurgical.co.za/?p=2717</guid>

					<description><![CDATA[<p>Instrument reprocessing runs in one direction: point of use, decontamination, inspection, packing, sterilization, storage. Each step, and where departments slip.</p>
<p>The post <a href="https://robdyersurgical.co.za/instrument-reprocessing-step-by-step/">Instrument Reprocessing from Start to Finish</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		
			</item>
		<item>
		<title>Pass-Through Autoclaves: The Double-Door Barrier, Explained</title>
		<link>https://robdyersurgical.co.za/pass-through-autoclave-double-door/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 16 Oct 2026 09:54:09 +0000</pubDate>
				<category><![CDATA[Autoclaves & Sterilizers]]></category>
		<category><![CDATA[autoclaves]]></category>
		<category><![CDATA[CSSD]]></category>
		<category><![CDATA[RDS Series]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">https://robdyersurgical.co.za/pass-through-autoclave-double-door/</guid>

					<description><![CDATA[<p>What a pass-through autoclave is, how the double-door interlock keeps clean and sterile zones apart, and what the wall has to carry one.</p>
<p>The post <a href="https://robdyersurgical.co.za/pass-through-autoclave-double-door/">Pass-Through Autoclaves: The Double-Door Barrier, Explained</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		
			</item>
		<item>
		<title>Pre-vacuum and gravity displacement: reading an autoclave cycle</title>
		<link>https://robdyersurgical.co.za/pre-vacuum-vs-gravity-autoclave-cycles/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 16 Oct 2026 06:00:00 +0000</pubDate>
				<category><![CDATA[Autoclaves & Sterilizers]]></category>
		<category><![CDATA[autoclaves]]></category>
		<category><![CDATA[CSSD]]></category>
		<category><![CDATA[Steam Sterilization]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">https://robdyersurgical.co.za/?p=2713</guid>

					<description><![CDATA[<p>Pre-vacuum and gravity displacement cycles sterilize different loads. Here is how each autoclave cycle type works, and how to match cycle to load.</p>
<p>The post <a href="https://robdyersurgical.co.za/pre-vacuum-vs-gravity-autoclave-cycles/">Pre-vacuum and gravity displacement: reading an autoclave cycle</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		
			</item>
		<item>
		<title>How to Choose an Autoclave for Your Clinic or Day Hospital</title>
		<link>https://robdyersurgical.co.za/choosing-autoclave-clinic-day-hospital/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 13 Oct 2026 06:00:00 +0000</pubDate>
				<category><![CDATA[Buying Guides]]></category>
		<category><![CDATA[autoclaves]]></category>
		<category><![CDATA[Healthcare Facilities]]></category>
		<category><![CDATA[Standards Compliance]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">https://robdyersurgical.co.za/?p=2712</guid>

					<description><![CDATA[<p>Choosing an autoclave for your clinic means matching chamber size, cycle type, utilities and validation to your real daily load. Here is what to weigh.</p>
<p>The post <a href="https://robdyersurgical.co.za/choosing-autoclave-clinic-day-hospital/">How to Choose an Autoclave for Your Clinic or Day Hospital</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		
			</item>
		<item>
		<title>Autoclave Water Consumption: The 20 Litre Difference</title>
		<link>https://robdyersurgical.co.za/autoclave-water-consumption/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 26 Sep 2026 16:45:15 +0000</pubDate>
				<category><![CDATA[Autoclaves & Sterilizers]]></category>
		<category><![CDATA[autoclaves]]></category>
		<category><![CDATA[Healthcare Facilities]]></category>
		<category><![CDATA[RDS Series]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">https://robdyersurgical.co.za/autoclave-water-consumption/</guid>

					<description><![CDATA[<p>Conventional sterilizers can drink around 100 litres of water per cycle. Modern RDS designs use up to 20 L — here is why that matters for cost and sustainability.</p>
<p>The post <a href="https://robdyersurgical.co.za/autoclave-water-consumption/">Autoclave Water Consumption: The 20 Litre Difference</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		
			</item>
		<item>
		<title>Autoclave Validation: IQ, OQ and PQ Explained</title>
		<link>https://robdyersurgical.co.za/autoclave-validation-iq-oq-pq/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 26 Sep 2026 16:44:34 +0000</pubDate>
				<category><![CDATA[Autoclaves & Sterilizers]]></category>
		<category><![CDATA[autoclaves]]></category>
		<category><![CDATA[CSSD]]></category>
		<category><![CDATA[Healthcare Facilities]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">https://robdyersurgical.co.za/autoclave-validation-iq-oq-pq/</guid>

					<description><![CDATA[<p>Validation proves an autoclave does what it claims, every cycle. What IQ, OQ and PQ mean, what each stage tests, and who performs them.</p>
<p>The post <a href="https://robdyersurgical.co.za/autoclave-validation-iq-oq-pq/">Autoclave Validation: IQ, OQ and PQ Explained</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		
			</item>
		<item>
		<title>CSSD Workflow: The Sterile Department, Zone by Zone</title>
		<link>https://robdyersurgical.co.za/cssd-workflow-zone-by-zone/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 26 Sep 2026 16:42:06 +0000</pubDate>
				<category><![CDATA[Autoclaves & Sterilizers]]></category>
		<category><![CDATA[autoclaves]]></category>
		<category><![CDATA[CSSD]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">https://robdyersurgical.co.za/cssd-workflow-zone-by-zone/</guid>

					<description><![CDATA[<p>How a well-run CSSD moves instruments from soiled to sterile: the five zones, the barrier principle, and the equipment behind each step.</p>
<p>The post <a href="https://robdyersurgical.co.za/cssd-workflow-zone-by-zone/">CSSD Workflow: The Sterile Department, Zone by Zone</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		
			</item>
		<item>
		<title>Unveiling the RDS Series Autoclaves</title>
		<link>https://robdyersurgical.co.za/unveiling-the-rds-series-autoclaves/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 06 Jan 2025 06:09:08 +0000</pubDate>
				<category><![CDATA[Autoclaves & Sterilizers]]></category>
		<category><![CDATA[autoclaves]]></category>
		<category><![CDATA[CSSD]]></category>
		<category><![CDATA[Laboratory Equipment]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[RDS Series]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">https://robdyersurgical.co.za/?p=1770</guid>

					<description><![CDATA[<p>Inside the RDS Series: single-door and pass-through autoclaves with high-efficiency vacuum, LDX2101 chambers and layered safety protection.</p>
<p>The post <a href="https://robdyersurgical.co.za/unveiling-the-rds-series-autoclaves/">Unveiling the RDS Series Autoclaves</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		
			</item>
		<item>
		<title>What are Flash Autoclaves used for?</title>
		<link>https://robdyersurgical.co.za/what-are-flash-autoclaves-used-for/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 16 Feb 2023 04:21:26 +0000</pubDate>
				<category><![CDATA[Autoclaves & Sterilizers]]></category>
		<category><![CDATA[autoclaves]]></category>
		<category><![CDATA[CSSD]]></category>
		<category><![CDATA[disinfection]]></category>
		<category><![CDATA[flash autoclave]]></category>
		<category><![CDATA[Medical Devices]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">https://robdyersurgical.co.za/?p=1481</guid>

					<description><![CDATA[<p>Flash autoclaves sterilise instruments in minutes, not hours. What they're used for in theatres, labs and pharma — and how the steam cycle works.</p>
<p>The post <a href="https://robdyersurgical.co.za/what-are-flash-autoclaves-used-for/">What are Flash Autoclaves used for?</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		
			</item>
		<item>
		<title>The Importance of Bedpan Washers in Modern Healthcare Facilities</title>
		<link>https://robdyersurgical.co.za/the-importance-of-bedpan-washers-in-modern-healthcare-facilities/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 07 Jan 2023 17:32:08 +0000</pubDate>
				<category><![CDATA[Bedpan Washers]]></category>
		<category><![CDATA[disinfection]]></category>
		<category><![CDATA[Healthcare Facilities]]></category>
		<category><![CDATA[Sluice Room]]></category>
		<category><![CDATA[sterilization]]></category>
		<guid isPermaLink="false">http://localhost/wordpress/?p=759</guid>

					<description><![CDATA[<p>Bedpan washer-disinfectors automate one of the highest infection-risk tasks in healthcare. How they work, and how they cut labour, water and waste.</p>
<p>The post <a href="https://robdyersurgical.co.za/the-importance-of-bedpan-washers-in-modern-healthcare-facilities/">The Importance of Bedpan Washers in Modern Healthcare Facilities</a> appeared first on <a href="https://robdyersurgical.co.za">Rob Dyer Surgical</a>.</p>
]]></description>
		
		
		